Infectiepreventie op het OK-complex Module 1.2.1 Tabel 1
Table 1. Characteristics of the included studies
Study |
Systematic review |
Country |
Type of surgery |
Procedure |
Participants |
Glove manufacturer |
Outcome |
Outcome assessment |
---|---|---|---|---|---|---|---|---|
Doyle, 1992 |
TM |
United Kingdom |
Obstetric and gynecology surgery |
Procedures involving sharp instruments |
Surgeons Surgeon assistants |
Not reported |
Inner and outer glove perforation |
Water leak method (500 ml, squeeze) |
Gani, 1990 |
TM |
Australia |
General surgery |
Different types of procedures, excluding microsurgical procedures |
Surgeons Surgeon assistants Scrub nurses |
Ansell |
Inner and outer glove perforation |
Water leak method (500 ml) |
Guo, 2012 |
Z |
China (Hongkong) |
Multiple surgical specialties (no orthopedic surgery) |
Different abdominal procedures |
Scrub nurses |
Ansell |
Inner and outer glove perforation |
Air inflation method Water leak method (no further details) |
Jensen, 1997 |
TM |
Denmark |
Abdominal surgery |
Not specified |
Surgeons Surgeon assistants |
Ansell |
Inner and outer glove perforation |
Water leak method (no further details) |
Kovavisarach, 1998 |
TMZ |
Thailand |
Obstetric and gynecology surgery |
Perineorrhaphy |
Surgeons |
Not reported |
Inner and outer glove perforation |
Air inflation method |
Kovavisarach, 1999 |
TMZ |
Thailand |
Obstetric and gynecology surgery |
Caesarean section |
Surgeons |
Ansell |
Inner and outer glove perforation |
Air inflation method |
Kovavisarach, 2002 |
TMZ |
Thailand |
Obstetric and gynecology surgery |
Abdominal hysterectomy |
Surgeons |
Ansell |
Inner and outer glove perforation |
Air inflation method |
Makama, 2016 |
Z |
Nigeria |
Multiple surgical specialties (no orthopedic surgery) |
Different types of procedures |
Surgeons Surgeon assistants Scrub nurses |
Ideal Medical Industries |
Inner and outer glove perforation |
Air inflation method Water leak method (no further details) |
Punyatanasakchai, 2004 |
TMZ |
Thailand |
Obstetric and gynecology surgery |
Perineorrhaphy |
Surgeons |
Medigloves |
Inner and outer glove perforation |
Water leak method (500 ml, squeeze) |
Rudiman, 1999 |
TM |
Indonesia |
General surgery |
Laparotomy |
Surgeons Surgeon assistants |
Johnson and Johnson |
Inner and outer glove perforation |
Water leak method (500 ml) |
Thomas, 2001 |
TMZ |
India |
General surgery |
Surgical procedure lasting more than 1 hour |
Surgeons Surgeon assistants |
Dial Rubber Industries |
Inner and outer glove perforation |
Air inflation method Water leak method (no further details) |
Wilson, 1996 |
TM |
Oman |
Multiple surgical specialties |
Different types of procedures |
Surgeons |
Not reported |
Inner glove perforation |
Water leak method (squeeze) |
T = Tanner, 2009; M = Mischke, 2014; Z = Zhang, 2021